PROGRAMMING WORK AND PAUSE TIMES
During programming the control unit has a self-learning capability with regard to work and pause times.
The S/S command will be activated several times during programming (item 7 of Fig. 1), alternatively the PP
command can be used (terminal 8 if Fig. 2 or the remote control (if stored). There are two types of installation and
different mode:
1) Installation with limit switches.
During programming the limit switch activates to determine the limit of gate movement. Follow type 1 for
programming.
2) System without limit switches.
During programming the anti-crush card MAS100 activates (Encoder) to determine the limit of gate movemet.
Follow type 1 for programming.
3) Should there be no limit switches and the anti-crush card MAS100 is not inserted, the times should be set
through the P/P control. Follow type 2 for programming.
Important notes before programming:
A. Power the control unit and check correct operation of the control inputs through the relative LEDs (the
N.C. contact LEDs should be on).
B. Free the area of gate movement.
FULL opening programming: Typology 1.
AUTOMATION WITH ELECTRIC LIMIT SWITCHES
1)
Shut off power supply to control unit
2)
Position the gate or door at mid-travel.
3)
Press PROG/STOP button
4,5,6) Switch on power to control unit by keeping the PROG./STOP button (part 6 of fig.1) pressed for at least 3 seconds.
Programming LED L1 comes on.
The same function can be obtained by holding the PROG./STOP button (part 6 of fig.1) down, shorting the reset pins (part
15 of fig.1) for a moment, then releasing the PROG./STOP button when LED L1 comes on.
7)
Press the P/P button (part 7 of fig.1). The motor then starts a closing manoeuvre. If the motor is running backwards,
cut off the power, invert the motor phases and the limit switches and repeat the procedure.
8,9)
Once the motor has reached the stroke limit, it stops and then the opening stroke starts automatically.
10)
During the opening, press the P/P button at the point at which you want to the gate to decelerate (optional)*.
11)
Once the opening stroke is complete, the motor stops. The control unit starts the pause time registration phase.