INSTRUCTIONS FOR INSTALLING THE ELECTRONIC CONTROL UNIT T101
Please read these instructions carefully before installing the control unit.
Improper use or a connection error could jeopardise correct operation of the product and endanger
the end user.
PART DESCRIPTION (Fig. 1)
1) Terminal board for primary transformer connection
3) 24 V 0.3 A fuse
4) Terminal
board
connection
5) Terminal board for limit switch connection
6) STOP/PROG Pushbutton for Programming and
Stop*.
7) P/P Step/Step button
8) Trimmer for motor power adjustment
9) Jumper Jp1 (for motor power cut-out and soft-start)
10) Connector for OC2 series receiver
11) Function dip-switch
12) TEST jumper
13) Encoder connector
* This STOP button must never be considered a safety device, but exclusively a service function to facilitate tests
during installation.
MODELS
Descriptions of the control unit models:
T101:
control unit for automation of 1 motor
T101F:
control unit for the automation of 1 motor for up-and-over doors
T101FA: control unit with transformer for the automation of 1 motor for up-and-over doors
The control units are equipped with:
- encoder input
- electronic torque adjustment
- motor deceleration
- motor brake
- self-diagnostics of the motor control (Triac Test)
- photocell operation check (Photo Test)
- Soft Start
Important notes:
If motors with internal limit switches are used, for example motors for shutters, the deceleration function must be
switched off (dip 9 OFF), the brake must be switched off (dip 8 OFF) and jumper JP1 fitted (part 9 of fig. 1).
Do not use the deceleration function with hydraulic motors. The gate must always be equipped with mechanical
end stops.
40
for
secondary
transformer
14) Terminal board for low tension connections (24V)
15) ECU reset. Shorting the 2 pins for a moment has the
same effect as switching power off then on again.
16) Indicators LEDs for terminal board inputs. LED on =
input closed
17) Programming LED (L1)
18) Connector for Electric Lock Module
19) Terminal board for 230 V connections
20) Terminal board for mains power supply input
21) 6.3 A fuse for line
22) Terminal board for motor and capacitor connection