5.2) Purging air bubbles from the internal hydraulic circuit
The operations of connecting and disconnecting the flexible hose and hydraulic heads could
7
cause air bubbles to form in the hydraulic circuit over time, adversely affecting the performance
6
of the pump.
To purge air bubbles from the circuit proceed as follows:
1
– Connect the hose and the hydraulic head to the pump.
– Place the hydraulic head onto a flat surface, keeping it in a vertical position.
8
– Leave the pump in inclined position (see Fig. 8) at a height approximately 1,5 m (4.9 ft)
higher than the head.
– Operate push button until the pressure switch intervenes.
– Completely discharge the oil pressure pushing the release button.
– Repeat at least 3-4 times to ensure all bubbles collect in the upper part of the reservoir.
– Check the oil level, topping up if necessary (see § 5.1).
6. FAULT DIAGNOSIS
200
SYMPTOM

POSSIBLE CAUSES

The pump does not start when
Discharged battery.
the remote controller push
button.
Incorrect connection of the
remote controller plug.
The pump starts but immedia-
Incorrect connection of the high
tely stops.
pressure hose to the pump or to
the hydraulic head.
Insufficient oil in the reservoir.
The pump starts but the oil is
not pressurised.
Air in the internal hydraulic circuit
No advancement, slow or pusa-
of the pump.
ting advancement of the ram of
the hydraulic head connected
to the pump.
After long use the pump will
The thermal switch has triggered
not start.
because of motor overheating.
See TABLE 2
Voir TABLEAU 2
It is not possible to couple the
Residual pressure of the oil in
siehe TABELLE 2
10
flexible hose to the pump.
the hose.
Ver TABLA 2
Vedere TAVOLA 2
If after these actions, the pump still does not operate correctly, please return it to Cembre (see § 7).
8
ENGLISH
(Ref. to Fig. 8)
7
6
19
18
REMEDY
Charge the battery (see § 3.5)
Connect plug correctly and secu-
re with the locking bezel
(see § 3.1).
Check the quick couplers for cor-
rect connection (see § 3.1).
Top up the oil reservoir
(see § 5.1).
Purge air bubbles in the internal
hydraulic circuit
5
(see § 5.2).
Allow the pump to rest and wait
until the motor has cooled down.
Connect the flexible hose to
the pump keeping the release
button pushed.