ve
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector
in terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Power Supply Cord—
Connect ground wire
Remove the green grounding screw and place
through the ring terminal of the green ground wire.
Reattach and tighten the green screw.
Power Cord—Connect
remaining wires
les
clay,
NOTE: Twist on wire connector. Gently tug on wires to be
sure both are secured.
Connect wires black to black and white to white, using UL
Listed/CSA Approved twist-on wire connectors (included
with power supply cord kit).
Wiring configuration
Power supply wire:
Terminal box wire:
white <—
white
black ~«——»-
black
ground wire «———». ground connector
If needed, see website for animated
representation of this
step. Visit www.whirlpool.com
under FAO tab.
Power Cord—Secure cord
on strain relief
Power Cord—Reinstall
terminal box cover
Place wires inside terminal box. Insert tabs
on left side of cover. Make sure wires are tucked inside
box. Close cover ensuring wires are not pinched.
Use 14"
nut driver and previously removed screw to secure
cover.
NOTE:
Do not plug into outlet until instructed to do so.
Determine Cabinet Opening
1 | Measure cabinet opening