Message/symptom
Display: "- - -
No air at HAP
No vacuum at desoldering tool
Incorrect status indication by VAC
LEDs
No display function
(display OFF)
VAC LED red
"Err" display
Display "OFF"
Replacing the filter
1. Turn the cover cap for "VAC" (14) or "AIR" (15) 45°
counterclockwise and remove.
2. Pull out the contaminated filter and dispose of properly.
3. Insert an original WELLER filter cartridge.
Make sure that the cover seal is properly seated.
4. Insert pressure spring.
5. Abdeckkappe unter leichtem Druck wieder aufsetzen und um
turn clockwise 45°.
10 Error messages and error clearance
Possible cause
 Tool has not been detected
 Tool defective
 DSX 80 Desoldering iron and
HAP 1 hot air tool are connected
simultaneously
 Air hose not or incorrectly
connected
 Vacuum hose not or incorrectly
connected
 Desoldering nozzle clogged
 Pressure-gauge level not
correctly set
 No mains supply voltage
 Vacuum system clogged
 VAC filter clogged
 Desoldering iron connected to
VAC
 Hot air tool connected to Vac
 Total power output of
connected tools more than
250 W
 Deactivate channel
Remedial measures
 Check connection of tool to device
 Check connected tool
 Disconnect one of the tools
 Connect air hose to AIR nipple
 Connect vacuum hose to VAC nipple
 Maintain desoldering nozzle with
cleaning tool
 Set pressure gauge level in
Special menu 2
 Turn on mains power switch
 Check mains supply voltage
 Check device fuse
 Clean suction nozzle
 Check filter (13) if yellow, then
replace
 Clean desoldering tool – replace filter
 Check vacuum hose
 Replace VAC filter
 Disconnect desoldering iron hose
 Connect hot air tool to AIR channel
 Acknowledge error with
┌ 2 ┐button
 Change tool selection and
activate channel
 Activate channel by briefly
pressing UP and DOWN buttons
simultaneously