WR 2
Defining the pressure-gauge threshold
 This function can be used to define the maintenance interval of
the desoldering tool. Here the value in mbar at which the electric
pressure gauge issues a warning signal when the intake system is
contaminated (LED (3) of the vacuum pump switches from green
to red) is defined. The set value is dependent on the suction
nozzles used.
 Factory setting: -600 mbar
Adjustable: -400 mbar to -800 mbar
1. The system (tips and filter) must be free
2. Select the menu item LEVEL in Menu 2.
3. Set the LEVEL pressure value with the UP or DOWN button.
The check LED switches back and forth between red and green.
Use the UP button to increase the vacuum by 50 to 80 mbar, to
compress the vacuum hose and to check whether the indicator
lamp switches from green to red.
4. Change to the next menu option using the ┌ 1 ┐ (back) or ┌1·2 ┐
(forwards) button.
Setting the station identification (ID code)
An ID code can be assigned to each station so it can be clearly
identified.
1. Select the menu item REMOTE ID in Menu 2.
2. Enter an ID with the UP or DOWN button.
(possible values 0 – 999).
3. Change to the next menu option using the ┌ 1 ┐ (back) or ┌1·2 ┐
(forwards) button.
Note
Press button ┌ 2 ┐ to exit the menu item without changes (EXIT).