Télécharger Imprimer la page

Adventys GL2 3000 DIR Guide D'utilisation page 15

Publicité

Les langues disponibles

Les langues disponibles

Technictli apecificttiona
Modeli:
Ntme:
Mttéritlia:
Power:
Eliectricity auppliy:
Current:
Controlia
Dimenaiona of tppliitnce:
Dimenaiona of the vitrocertmic glitaa:
Dimenaiona of the inductor:
Dimenaiona minimum of the ptn:
Mtximun weight tliliowed on the tppliitnce:
Net weight of the tppliitnce:
Emission of electromagnetic radiation not
ionisante for the human body. The emitted
energy is insufficient to cause the ionization.
Eliectrictli connection
For veraion 3000W:
Connect your device on the adapted electric socket of a single-phase network 230 V, 50 Hz.
For veraion 5000W / 6000W / 7000W :
Connecting on t 32A eliectric aocket on ainglie-phtae network 208 / 240V 50 Hz :
Connect the BLUE/ BROWN wire on NEUTRAL of the electric socket.
Connect the GREY wire and BLACK wire on PHASE of the electric socket.
Connect the GREEN and YELLOW wire on GROUND of the electric socket.
Connecting on three-phtae network 400V 50 Hz 16A by phtae:
Connect the BLUE/ BROWN wire on NEUTRAL of the electric socket.
Connect the GREY wire on PHASE_1 of the electric socket.
Connect the BLACK wire on PHASE_2 of the electric socket.
Connect the GREEN and YELLOW wire on GROUND of the electric socket.
GL2 DIR
Drop in induction hob
Stainless steel
3000W 3500W / 5000W, 6000W or 7000W depend of the version
single phase 230V +/-10% 50Hz
6,5Ax2 (3000W) / 8Ax2 (3500W) / 11Ax2 (5000W) / 13Ax2 (6000W) /
16Ax2 (7000W)
4 Mecanics touches and timer
W 350 X D 699 X H 182 mm
W 262 X D 663 X H 4 mm
2 x 210 mm
16 cm
2 x 20 kg
12,5 Kg
CAUTION: presence of dangerous
tension inside the product.
15

Publicité

loading

Ce manuel est également adapté pour:

Gl2 3500 dirGl2 5000 dirGl2 6000 dirGl2 7000 dir