CONNECTION OF THE ELECTRIC CABLE TO THE ELECTRICITY
Instalation of electric feeder - This feeder must be separetely protected by a safety fuse according to the
specifi c electric stream which depends on the wattage of the instaled device. Check the wattage on the label
at the back of the device. Connect the device directly to the electricity but you must put the switch between
the device and electric net. The switch must be placed in min. distance 3 mm between the particular contacts
according to the standards and loading. The feeder of grounding (yellow-green) cannot be interrupted by this
switch. In every case feeding cable must be placed so that no point of the cable will reach the temperature
which is 50°C higher than the temperature of the surrounding. Before connecting the device check that:
• safety fuse of the feeder and inner mains can stand the loading of the device (see label of the matrix)
• mains are equipped with effective grounding according to standards (ČSN) and conditions given by law
• socket or switch of the feed is well accessible from device
We refuse any responsibility in case of not respecting above mentioned rules. Before the fi rst use it is
necessary to remove all the protection foil and to clean the device - see chapter „cleaning and maintenance".
Maintenance: We recommend to have the device checked once a year by the proffesional service. Only
qualifi ed or competent persons can do interventions in the product.
-Do not insert the power cable plug into the el. socket and do not pull it out of the
el. socket with wet hands or by pulling on the cable!
-Do not use extension cables or power strips.
WATER CONNECTION
Water connection is performed with hose threaded G1/2. The water supply must be equipped with a separate
valve which is freely available and within range of the device. The equipment includes a check valve.
• Water hardness must be in range 0,5 - 5 ° French degree.
IF HIGHER, IT IS NECESSARY USE WATER SOFTENING SYSTEM.
• Water pressure must be within range 50 - 250kPa.
• Volume of chlorine in the water shall not be higher than 10ppm, or you risk bath surface damage
• Acidity of water must be higher than 7 pH.
• Electrical conductivity: 50 - 2000uS/cm (20°C)
• The connection must be made according to directive EN 1717 and with valid to national directives for aqua-
culture.