Operation with batteries (internal power supply)
Indicator
Fault
flashing
Flame not ignited
3
brightly
8
Burner defective or coo-
flashing
3
ling unit defective
brightly l
7
Acoustic signal at 15
Undervoltage detection
(internal batteries)
second intervals
Refrigerator does not
Automatic
switching
function;
from external to internal
gas operation not possi-
power supply does not
ble although the batte-
function
ries are inserted.
(absence of the on-
board 12 V power sup-
ply for the electronics)
All manuals and user guides at all-guides.com
Remedy
Check gas supply (gas bottle, gas valve)
Press the
Check burner, burner nozzles, if necessary contact
Customer Service and arrange replacement
Replace batteries
Switch off the refrigerator and start again.
The on-board power supply was interrupted during
the starting of the gas operation.
Note: No automatic switching is performed during
the ignition.