which are installed on the reflector mounting bolt in the fan
housing. Adjust the height of the reflector mounting bolt so that
the grill will be tight up against the finished ceiling and less than
1/4" of the reflector mounting bolt protrudes through the reflector.
Secure the reflector bolt's position by tightening the factory
installed nut against the motor clip (Figure 11).
Lock Washer
Acron Nut
Figure 11
CAUTION:
FAILURE TO SECURE THE REFLECTOR BOLT MAY
RESULT IN A RATTLING OR HUMMING NOISE.
3. After the reflector bolt is secure, raise the grill/reflector up
into position, and plug the reflector into the appropriate
receptacle. Secure the assembly to the reflector bolt using
the acorn nut and lock washer. Install the appropriate bulb
(not included) specific to your model:
ASLC50/ASLC70: 100 watt maximum, type A19 medium
base incandescent bulb.
ASLC50FL: 13 watt maximum, 2 pin quad, compact
flourescent bulb.
ASF50/ASF70: 26 watt, triple 4 pin flourescent bulb.
NEMA model: CFM26W/GX24q/27, 30, 35, 41
Sylvania model: CF26DT/E/IN/835, 841
Phillips model: PL-T 26W/30, 35, 41/4P
GE model: F26BX/SPX30, 35, 41/A/4P
Reinstall the lens into the grill (Figure 12).
Figure 12
4. Restore power and test your installation.
210572120 Rev. D 7-06
All manuals and user guides at all-guides.com
Motor Clip
Mounting Bolt
Nut
Reflector
Grill
Lens
Tabs
SECTION 7
Use and Care
CAUTION:
SERVICE PANEL BEFORE SERVICING THE UNIT.
1. Cleaning the Grill: Remove grill and use a mild detergent,
such as dishwashing liquid, and dry with a soft cloth. NEVER
USE ANY ABRASIVE PADS OR SCOURING POWDERS.
Completely dry grill before reinstalling. Refer to instructions
in Section 6 Completing the Installation , to reinstall grill.
2. Cleaning the Fan Assembly: Unplug the motor cord and light
cord from receptacles and loosen the venturi screw to remove
the venturi from the unit. Wipe all parts with a dry cloth or
gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS
IN WATER. Refer to instructions in Section 6 Completing the
Installation , to reinstall venturi.
CAUTION:
3. Changing the Light Bulb: Disconnect power to the unit.
Remove the light lens by squeezing at the tabs and pulling
down (Figure 13). Remove light bulb and refer to instructions
in Section 6 Completing the Installation , to complete the light
bulb change and installation of light lens.