Télécharger Imprimer la page

Bosch ISN-SM-50 Instructions D'installation page 22

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Appendix
Anhang
Additional UL requirements
1.
Installation
For a complete safe and vault installation connect to 'high security cable'. This
product shall be installed in accordance with The Canadian Electrical Code,
Part 1, Safety Standard for Electrical Installations.
2.
Programming - Sensitivity
Remote input (terminal 7) must not be able to be activated manually. It
has to be assured that remote input is only active while functional noise
requires its activation.
Remote input must not be activated permanently and is limited to
60 seconds.
2.1.
Sensitivity settings verified by UL for Monolithic Concrete:
Minimum
Maximum
thickness
spacing
2.5m
8.2ft
0.6m
1.98ft
4.0m
13.2ft
5.0m
16.5ft
For coverage of surfaces over corners, the recommended spacing is
reduced by 75%.
2.2.
Sensitivity settings verified by UL for Modular Steel Panels:
Minimum
Maximum
thickness
spacing
1.0m
3.3ft
0.006m
0.25in
1.5m
4.9ft
2.0m
6.6ft
A detector shall be on each modular wall panel that is not continuously
welded.
For coverage of surfaces over corners, the recommended spacing is
reduced by 75%.
2.3.
Sensitivity settings verified by UL for Steel Safes:
Minimum
Placement
thickness
Body
0.006m
0.25in
Door
Body
0.006m
0.25in
Door
Body
0.006m
0.25in
Door
At least one detector is to be mounted on the door and at least one
detector is to be mounted on the body.
* Note: Shock sensitivity is defined as the sensitivity to single impacts on the
detector or its base. Only in USER MODE, the shock sensitivity can be set
independently of Mode and Operating radius with the help of the ISN-SMS-W7
SensTool Software. If one of the fixed DIP setting is used, the shock sensitivity
corresponds to Mode and Operating radius as indicated in the tables above.
Requisiti supplementari dell'IMQ
Omologazione IMQ CA12.00766
1.
Specifiche tecniche
Livello di prestazione
Temperatura di funzionato
Grado di protezione
l'assorbimento di corrente
immunità ai campi elettromagnetici10V/m−0.08
Accessori non sono coperti dalla certificazione:
set da incasso
scatola da pavimento
Emisor de ensayo
F.01U.326.907-01
Annexe
Appendice
All manuals and user guides at all-guides.com
Mode and
Shock
operating radius
sensitivity *
Concrete 2.5m
High
Concrete 4m
High
Concrete 5m
High
Mode and
Shock
operating radius
Sensitivity*
Steel
Low
1m
Steel
Mid
1.5m
Steel
Mid
2m
Mode and
Shock
Maximum
operating
sensitivity*
spacing
radius
Steel
1.0m 3.3ft
Low
1m
Steel
1.5m 4.9ft
Mid
1.5m
Steel
2.0m 6.6ft
Mid
2m
II° livello
+5 ºC fino a +40 ºC
IP30
4 mA
2 GHz
ISN-GMX-W0
ISN-GMX-B0
ISN-GMX-S1
Anexo
2.
Accessori
Disposizione di prova ISN-GMX-S1
Piastra copritoppa GMXP3 GMXP3Z
Exigences supplémentaires de NF&A2P
1.
Fixation
Toutes les exigences relatives aux agréments nationaux et concernant
l'application du produit doivent être satisfaites.
2.
Câblage du détecteur
Le câblage peut être réalisé avec du câble souple de 0,22mm ou du câble de
type SYT.
3.
Accessoires
ISN-GMX-D7Feuille anti-perçage
Cette option n'est pas disponible en France.
ISN-GMX-W0 Jeu pour encastrement mural avec couvercle
mode de protection selon (EN 60529)
capabilité max. de porter du couvercle
ISN-GMX-B0 Boite de sol
mode de protection selon (EN 60529)
capabilité max. de porter du couvercle
4.
Caractéristiques techniques
Tension d'alim: 8,0 Vcc ....... 16 Vcc; ondulation résidu..: 0,25 Vac
Bande de fréquences :........................................13 à 19 KHz
protection du boîtier (EN 60529, EN 50102) ...............IP43, IK07
5.
Certificat NF&A2P 3 boucliers N° 2730000350A0
Référentiel NF324-H58
ISN-SM-50
ISN-GMX-S1
ISN-GMX-P0
ISN-GMX-W0
ISN-GMX-B0
ISN-SMS-W7
6.
Organisme certificateur :
CNPP Cert.: www.cnpp.com
AFNOR Certification: www.afnor.org
Zusätzliche Anforderungen von VdS
1.
Anwendung
1.
Das Gerät eignet sich zum Einsatz in Einbruchmeldeanlagen nach
DIN EN 50131-1.
2.
Die Einstellposition „Digitaler Filter" in der Betriebssoftware SensTool
darf nicht verändert werden. Werkseinstellung: OFF
2.
Programmierung
Wird der Steuereingang Klemme 7 "Remote" zur Empfindlichkeitsreduktion
benutzt, so muss die Übereinstimmung mit den einschlägigen VdS-Vorschriften
im Systemzusammenhang geprüft, bzw. vom VdS akzeptiert werden.
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
www.boschsecurity.com
22
附件 [附件]
I° livello
I° livello
IP51
25 kg
IP51
1000 kg
273035-00
302302-02
302302-03
302302-08
302302-09
273034-06
© 2016 Bosch Security Systems, Inc.