Télécharger Imprimer la page

Stiebel Eltron SHC 10 Utilisation Et Installation page 9

Masquer les pouces Voir aussi pour SHC 10:

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Maintenance
13.1 Activate high limit safety cut-out
f Open the appliance (see chapter "Installation / Maintenance /
Opening the appliance").
f Pull off the adaptor.
f Press the reset button on the high limit safety cut-out.
f Fit the adaptor.
f Close the appliance cover.
f Fit the limiting ring and temperature selector.
1
1 Adaptor
2 Reset button, high limit safety cut-out
14. Maintenance
WARNING ELECTROCUTION
Before any work on the appliance, disconnect all poles
of the appliance from the power supply.
f Dismantle the appliance for maintenance work.
14.1 Checking the safety valve
f Check the function of the safety valve regularly.
14.2 Draining the appliance
WARNING Burns
Hot water may escape during the draining process.
f Drain the appliance via its connectors.
www.stiebel-eltron.com
2
14.3 Opening the appliance
f Pull off the temperature selector and the limiting ring.
f Remove the 4 screws from the casing.
f Open the appliance cover by pivoting the cover upwards and
then removing it.
f Remove the upper insulation semi-shell if required.
14.4 Removing the flanged immersion heater and
temperature controller / high limit safety cut-
out
1 Flanged immersion heater
2 Combined temperature controller / high limit safety cut-out
f Disconnect all wires from the combined temperature control-
ler/high limit safety cut-out.
f Remove the combined temperature controller / high limit
safety cut-out from the flanged immersion heater.
f Remove the flanged immersion heater.
1
2
SHC 10 | SHC 15 |
9

Publicité

loading

Ce manuel est également adapté pour:

Shc 10 gb eltronShc 15 stiebelShc 15 gb eltron