Télécharger Imprimer la page

Stiebel Eltron SHC 10 Utilisation Et Installation page 11

Masquer les pouces Voir aussi pour SHC 10:

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Specification
15. Specification
15.1 Dimensions and connections
SHC 10 | SHC 15 Stiebel
a20
c06
c01
100
a10
Appliance
Height
a20
Appliance
Width
a30
Appliance
Depth
c01
Cold water inlet
Male thread
Top clearance
c06
DHW outlet
Male thread
i13
Wall mounting bracket Height
Hole spacing
horizontal
a10
Appliance
Height
a20
Appliance
Width
a30
Appliance
Depth
c01
Cold water inlet
Male thread
Top clearance
c06
DHW outlet
Male thread
i13
Wall mounting bracket Height
Hole spacing
horizontal
www.stiebel-eltron.com
a30
80
i13
SHC 10 SHC 10 GB
Eltron
mm
430
430
mm
280
280
mm
270
270
G 1/2 A
G 1/2 A
mm
26,5
26,5
G 1/2 A
G 1/2 A
mm
320
320
mm
140
140
SHC 15 SHC 15 GB
Eltron
mm
452
452
mm
320
320
mm
318
318
G 1/2 A
G 1/2 A
mm
23
23
G 1/2 A
G 1/2 A
mm
342
342
mm
200
200
15.2 Wiring diagram
1/N/PE ~ 220-240 V
1
A
L
15.3 Heat-up diagram
The heat-up period depends on the degree of scaling and residual
heat. For the heat-up time for a cold water supply at 10 °C and a
maximum temperature setting, see the diagram.
40
35
30
25
20
15
10
5
0
35
40
45
x Temperature in °C
y Duration in min
1 15 l appliance
2 10 l appliance
15.4 Country-specific approvals and certifications
The test symbols can be seen on the type plate.
15.5 Extreme operating and fault conditions
In the case of faults, a peak temperature of up to 99 °C may briefly
occur in the system.
2
B
N
PE
1
2
50
55
60
65
SHC 10 | SHC 15 |