TROUBLE SHOOTING
Contact Princess Auto Ltd. for a solution if the tool does not function
properly or parts are missing. If unable to do so, have a qualified
technician service the tool.
Problem(s)
Tool runs at normal
speed but loses
power under load.
Tool runs slowly.
Air flows slightly
from exhaust.
Tool will not run.
Air flows freely
from exhaust.
Tool will not
shut off.
Visit www.princessauto.com for more information
Possible cause(s)
Motorparts worn.
Motor parts jammed
with dirt particles.
OR
Air flow blocked
by dirt.
Air Flow Regulator
is in the
closed position
O-rings throttle valve
dislodged from seat
inlet valve.
Damage or excessive
wearing of
internal parts.
Material buildup
impeding motor
vanes.
O-rings throttle valve
dislodged from seat
inlet valve.
Suggested solution(s)
Have a qualified technician
replace worn parts.
Check air inlet filter
for blockage.
Operate tool in
short bursts.
Disconnect air supply.
Free motor by rotating
drive shank manually
where applicable.
Repeat above as needed. If
this fails, bring to Princess
Auto Ltd. or to a
qualified technician.
Open regulator to
correct position
Have a qualified technician
replace the O-ring.
Bring to Princess Auto Ltd.
or a qualified technician.
Clean internal mechanism.
Bring to Princess Auto Ltd.
or a qualified technician.