4 TRIGGER MODE : When the torch trigger is pressed and released once, welding starts and there is no
need to hold it pressed until the welding ends. Pressing and releasing the trigger again will end the welding
process.
• Press and hold the torch trigger.
Welding Start;
• Shielding gas flow starts as long as the pre-gas period.
• At the end of the pre-gas period, the wire feed motor
runs at a slow speed.
• Welding current increases when the workpiece is
reached.
• Release the pressed torch trigger and the welding will
continue.
welding period and ends at the end of the period. No welding will be performed if as long as the defined void
METHOD : It is the pnt welding to be mentioned in the mode. The welding continues for the specified
period. This period will continue as long as the trigger is not released.
Welding Time : 0.2-9.9 and void time : It is between 0.0 and 9.9 seconds.
It should be preferred when the same welding seam and penetration are desired every time. The lengths
of the welds made in Method mode will be equal.
www.magmaweld.com
• Release the pressed torch trigger.
Welding Termination;
• The wire feed motor will stop.
• The arc extinguishes after the set burn-back time.
• The process ends after the final gas period.
PrG : Initial Gas Time
: Welding Current
PoG : Final Gas Time
I
Operation
29
EN
USER MANUAL