SMART SERIES
When the method is selected, the welding time is set.
Welding Time
Pon
No welding period is set when the method is selected.
Blank Time
PoF
Soft start setting is made.
Soft Start
SoS
When starting to weld, the wire speed gradually increases from low speed to the set speed.
In this way, knocks and splashes at the beginning of the welding are prevented.
Crater function setting is made.
Crater
Crt
It is the filling process to prevent cracks that will occur at the end of welding. When the
crater is active, the welding current is reduced with a certain linearity at the end of the
welding and the welding ends.
www.magmaweld.com
• 0.2 - 9.9 sn.
Setting Range
• 0.0 - 9.9 sec.
Setting Range
• On - Off
Setting Range
• On - Off
Setting Range
Operation