Kohler K-1696 Guide D'installation page 11

Masquer les pouces Voir aussi pour K-1696:

Publicité

Les langues disponibles

Les langues disponibles

240V 50/60Hz
Black
Line 1
Black
Line 2
4 X 40 AMP CLASS H FUSE
Earth Ground
Threaded Case
Ground Stud
5 VOLTS DC
RJ12
To UIC or
RS485
Adapter
5. Make Electrical Connections
DANGER: Risk of electrocution. Disconnect all power before performing these installation steps.
NOTICE: All electrical work should be done by a licensed electrician.
NOTICE: Do not install a GFCI to this unit. This will prevent nuisance tripping.
NOTICE: All electrical wiring must be done in accordance with local codes.
Turn off all electricity to the working area at the main breaker panel.
Connect 240 VAC electrical lines to the wires labeled "1" and "2" coming out of the steam generator.
NOTICE: The steam generator should have a dedicated circuit breaker.
6. Install the Steam User Interface Control
NOTE: Follow the instructions packed with your user interface control.
Operating the Steam User Interface Control
NOTE: Follow the instructions packed with your user interface control.
Troubleshooting Guide
NOTE: Refer to the information packed with your steam head and user interface control for help in
troubleshooting the system.
The troubleshooting guide is for general aid only. For service and installation issues and concerns, call
1-800-4-KOHLER.
Kohler Co.
Fuse Block
4 Pole
Black
Black
Black
Black
J7 J3
J2 J1
Power Supply Board
J4
J5
J6
Red
Thermo Switch
Level Switch
White
4 Pole Contactor
C1 C2
Black
L1
T1
Black
L2
T2
Black
L3
T3
Black
L4
T4
Power
Clean
Solenoid
LFuse 1A
165F
Thermostat
LFuse 1A
Tank
Preheater 85w
Inner Tank Assembly
11
Heater Element
Assemblies
Wiring Diagram
1053772-2-C