Remarks:
Test the device once a year to make sure it is still fully operational:
1. Dismount the unit, open the housing, check the PIR sensor and the mirror and wipe off dust and stains with a soft
cloth.
2. Mount the unit again and execute a walk test to verify whether the device still works according to the specifications
listed in the manual.
5. Specifications
Operating Voltage
Warm-Up Time
Stand-By Current
Operating Current
Operating Temperature
Mounting Height
Mounting Location
Relay Contact
Detection Range
Four Lenses
Detection Range
• wide-angle lens : min. 14m (45.9ft) x 110° wide (fan-shaped)
• long-range lens : min. 21m (68.8ft) x 20° wide
• pet lens
• curtain lens
Pulse-Count Mode
UL and RFI Test
EMS Test
6. Troubleshooting
PROBLEM
device does not function
test LED does not light when
triggered
two-pulse count mode does not
function normally
triggering does not activate main
unit alarm
HAA53
All manuals and user guides at all-guides.com
9 to 16Vdc
max. 1 minute
max. 25mA @ 12V DC. (measured at the end of the warm-up time)
max. 25mA @ 12V DC. (measured at the end of the warm-up time)
0 to 40°C
1.8m to 2.5m (5.9 to 8.2ft)
wall, corner, ceiling
0.5A @ 24V DC
adjustable from 5 to 14m (16.4 to 45.9ft)
wide-angle, long range, pet, curtain
min. 6m (19.6ft) x 180° wide (only left and right)
min. 6m (19.6ft) x 180° wide (only left and right)
: min. 12m (39.4ft) x 110° wide (fan-shaped)
: min. 14m (45.9ft)
one- or two-pulse count mode installed through jumper on P2 of PCB
RFI test at 100kHz – 1GHz
25V/m (refer to IEC 801-3).
CAUSE
no contact power line terminals (T5, T6)
no contact P1
no or bad contact P2
no contact terminal T1, T2, T3 or T4
5
SOLUTION
connect power lines
check jumper on P1
check jumper on P2
reconnect wires