Télécharger Imprimer la page

Selco Genesis 1700 AC/DC Manuel D'instructions page 39

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71
Enter the "Guard limits" screen by pressing the encoder button.
Select the required parameter by pressing button (1)
Select the method of setting the guard limits by pressing button
(2)
.
/
Absolute value
%
Percentage value
7 Warning limits line
8 Alarm limits line
9 Minimum levels column
10 Maximum levels column
Select the required box by pressing the encoder key (the select-
ed box is displayed with reverse contrast).
Adjust the level of the selected limit by rotating the encoder.
Save and exit the current screen by pressing button (4)
Passing one of the warning limits causes a visual signal to appear
on the control panel.
Passing one of the alarm limits causes a visual signal to appear
on the control panel and the immediate blockage of the weld-
ing operations.
It is possible to set start and end of welding filters to prevent
error signals during the striking and extinction of the arc (consult
the "Set up" section - Parameters 802-803-804).
3.11 Alarms screen
Allows the intervention of an alarm to be indicated and provides
the most important indications for the solution of any problem
encountered.
.
1
Alarm icon
2
Alarm code
3
Alarm type
Alarm codes
E01, E02, E03
Temperature alarm
E10
Power module alarm
E11, E19
System configuration alarm
E13
Communication alarm (FP)
E14, E15, E18
Program not valid alarm
.
E17
Communication alarm (μP-DSP)
E20
Memory fault alarm
E21
Data loss alarm
E22
Communication alarm (DSP)
E27
Memory fault alarm (
E28
Memory fault alarm (
E29
Incompatible measurements alarm
E30
Communication alarm (HF)
)
)
39

Publicité

loading

Ce manuel est également adapté pour:

Genesis 2200 ac/dc