1 | Information on this manual
1
Information on this manual
This document is a preliminary version of
the installation manual. Please note the rel-
evant version and date.
This manual describes how to set up
Combi-Duo for the following units:
LM1: iCombi Pro (iCP) 6-1/1 to
n
10-2/1
LM2: iCombi Classic (iCC) 6-1/1 to
n
10-2/1
This manual is to be used in addition to the
unit installation manual for iCombi Pro /
iCombi Classic. Read the manual before
assembly. The installation manual is there
to ensure that you use the units safely and
install them properly.
The illustrations in this installation manual
are examples only and may differ from the
unit.
You will find information on the water,
waste water, electrical connections, and
for gas units, on the gas and flue connec-
tions in the unit installation manual for
iCombi Pro / iCombi Classic.
All information from the unit installation
manual for iCombi Pro / iCombi Classic
apply accordingly.
2
Safety
This units are designed in such a way that
they present no danger if installed accord-
ing to instructions. This manual describes
how to install the Combi-Duo correctly.
Follow all safety instructions in the install-
ation manual for iCombi Pro / iCombi
Classic.
Adhere to the relevant local regula-
n
tions and standards in your country.
Only connect the unit in accordance
n
with the installation manual and the in-
formation on the rating plate.
80.51.370_iCombi Pro-iCombi Classic_CD E_IM_V02_EU-west
Switch the unit off before disconnect-
n
ing the mains power or connecting to
the mains.
Also note the following hazard warnings
when setting up the Combi-Duo:
WARNING
Risk of crushing and injury from
tipping or turning of the Combi-Duo
system.
Tipping or turning the Combi-Duo
system may make it fall off the
installation surface.
Do not tip the system onto the
n
installation surface.
When turning the body, make sure
n
that the weight of the equipment is
evenly distributed and that the feet
or castors of the base frame or the
levelling kit are on the installation
surface.
Secure the system using the
n
appropriate accessories from the
manufacturer.
WARNING
Risk of burns from hot exhaust pipes
and flue pipes
The exhaust and flue pipes can become
very hot when operating the Combi-
Duo system.
Do not touch the exhaust pipes
n
during operation.
For gas units: Do not touch the flue
n
pipes during operation.
en