Télécharger Imprimer la page

Specifications; Measured Values - Wohler Rf 220 Mode D'emploi

Masquer les pouces Voir aussi pour RF 220:
Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
2.

Specifications

2.1
Application
The Wöhler RF 220 Hygrotemp is a handy, handheld, battery powered instru-
ment designed for the quick determination of the air humidity in housing spaces
and workplaces.
It can be applied to control clima systems, to analyze structural damages, to
discover potential mould areas and so on.
The Wöhler RF 220 Hygrotemp measures the actual air humidity and tempera-
ture and calculates the dew point and the wet bulb by this values.
2.2

Measured values

Rel. Humidity:
RH range:
0 ... 100 % r.h.
Resolution:
0,1 % r.h.
Accurracy:
± 3 % r.h. (10 ... 90 % r.h.)
otherwise ± 5 % r.h.
Temperature:
RH range:
-20 °C ... 60 °C
Resolution:
0,1 °C
Accuracy:
± 1 °C
Dew point:
Dew point range:
-73 °C ... 59 °C
Wet bulb:
Wet bulb range:
-13 °C ... 59 °C
e-Mail: mgkg@woehler.de
Wöhler RF 220
http://mgkg.woehler.de
11
loading

Ce manuel est également adapté pour:

22112