3 Transport and interim storage

When receiving the material, check that there has
been no damage during the transport. If shipping
damage has occurred, take all necessary steps with
the carrier within the allowed time.
CAUTION! Outside influences may cause damages
If the delivered material is to be installed later on,
store it in a dry place and protect it from impacts
and any outside influences (humidity, frost etc.).
Handle the pump carefully so as not to damage the
unit prior to installation.
WARNING! Bodily injury
Due to the high centre of gravity and small pump
footprint, beware of instability during handling to
avoid the pump falling over.

4 Intended use (Application)

CAUTION! Possible damage of the pump
These pumps are intended for use with water only
Typical applications for the MVI pumps are clean flu-
ids relatively free of abrasive particles in commercial,
agricultural, industrial and municipal areas. Water
supply, water towers, irrigation, high pressure wash
down, fire protection, boiler feed, condensate return
and pressure boosting systems.
Application areas:
• water distribution and boosting installations
• industrial circulation systems
• process fluids.
• cooling water circuits.
• fire-fighting and washing stations.
• watering installations, etc.

5 Technical data

5.1 Type key
Example: MVI220-02/1-1/A3/E80/3-575-14-T
MVI
pump family
220
nominal flow in GPM at 60Hz / 2 poles
- 02
number of stages
/ 1
Number of reduced impellers
- 1
1
2
3
coated volute, 304 stainless steel hydraulic
/ A3
P
A3 = ANSI Flange 300 lb
O
4
= stainless steel 304
= stainless steel 316L
= pump casing cast iron cataphoresis
= Victaulic coupling
= 2 bolt oval flanges, NPT threaded
Example: MVI220-02/1-1/A3/E80/3-575-14-T
/ E
Pump Seals
E
= O rings: EPDM (KTW/WRC)
V
= O rings: VITON
80
Only 1 digit Means:
K
= Standard seals with cardridge
S
= Standard seals without cardridge
(EPDM or VITON materials depending
on pump seals)
2 digits means special executions:
00 = mechanical seal Silicon carbide / Sili-
con carbide EPDM
80 = mechanical seal Silicon carbide / Sili-
con carbide EPDM cardrige system
10 = mechanical seal Silicon carbide / Sili-
con carbide VITON
A0 = mechanical seal Silicon carbide / Sili-
con carbide VITON cardrige system
11 = mechanical seal Silicon carbide / Car-
bon VITON
01 = mechanical seal Silicon carbide / Car-
bon EPDM
/ 3
1
= Single phase
3
= Three phase
nothing = Without motor
- 575
1-230 = Single phase 115/230 V 60 Hz
3-460 = Three phase 208-230/460 V 60 Hz
3-575 = Three phase 575 V 60 Hz
- 14
56 = 56C NEMA Motor Frame
14 = 143TC & 145TC
18 = 182TC & 184 TC
21 = 213TC & 215 TC
28 = 284TC & 286 TC
32 = 324TSC
36 = 364 TSC
-T
O
= ODP Motor Enclosure
T
= TEFC
5.2
Data table
Maximum operating pressure
Pump casing
Oval flange: 230 PSI (16 bar)
ANSI flanges 300 lb: 360 PSI (25 bar)
"Victaulic" flanges: 230 PSI (16 bar)
Maximum suction
140 PSI (10 bar)
pressure
Temperature range
Liquid temperatures
EPDM Version: 5 °F to 250 °F
(- 15° to + 120 °C)
VITON Version: 5 °F to 194 °F
(- 15° to + 90 °C)
Ambient temperature +104 °F Max (+ 40 °C)