Safety Information For Inspection And Assembly; Unauthorized Modification And Manufacture Of Spare Parts; Transport And Interim Storage; Product And Accessory Description - Wilo Drain LP 40 Notice De Montage Et De Mise En Service

Masquer les pouces Voir aussi pour Drain LP 40:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.5 Safety information for inspection and assembly

The operator must ensure that all inspection and installation work is carried out
By authorised and qualified specialists who have carefully studied these
instructions. Work on the pump/machinery should only be carried out when the
machine has been brought to a standstill.

2.6 Unauthorized modification and manufacture of spare parts

Alterations to the pump or installation may only be carried out with the
manufacturer's consent. The use of original spare parts and accessories
authorised by the manufacturer will ensure safety. The use of any other parts
may invalidate claims invoking the liability of the manufacturer for any
consequences.
2.7 Unauthorised operating methods
The operating safety of the pump or installation supplied can only be guaranteed
if it is used in accordance with paragraph 1 of the operating instructions. The
limiting values given in the catalogue or data sheet must neither be exceeded nor
allowed to fall below those specified.

3 Transport and interim storage

ATTENTION!

4 Product and accessory description

4.1 Pump description (Fig. 1)
Pos. 1
Filling- / bleeding plug
Pos. 2
Drain plug
Pos. 3
Suction port
The Self priming Pump Wilo LP is driven by a dry-running motor which is fixed by
screws with the pump housing. Motor and pump have a continuous shaft made of
stainless steel. The impellers material is bronze. The pump housing is made of
polypropylene plastics. The flow medium enters from a horizontal suction opening and
exits by the vertical pressure connection. Both connections are equipped with 1 ½ "
plastic flanges.

4.2 Products delivered

 Installation and operating instructions
 Plastic flanges 1 ½". Suction and pressure.
 The pump may only be transported/suspended on the handle
provided for transport. Never by the cable. The pump must be
protected against physical damage
 The pump mustn't get into contact with flammable parts (clothes)
while using.
 If the Pump is not used for longer time it should be disconnected
from the electrical supplyment.
- 12 -
Pos. 4
Handle
Pos. 5
Discharge port
ENGLISH

Publicité

Table des Matières
loading

Table des Matières