WARNING  SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

Conversion to another gas

Check in the Technical Data section at
the back of the book that the cooker is
convertible to the gas you want to use.
This conversion must be performed by a competent person.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could invalidate
any warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest
of the appliance in struc tion, in particular for information on
Standards, cooker positioning, connection hose suitability
etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Disconnect from the electricity supply before commencing
servicing. Before electrical re-connection, check that the
appliance is electrically safe.
Injectors
Remove burner caps and heads. Remove old jets. Fit the
new jets. See the Technical Data section at back of the book
for the correct jets. Reassemble in reverse order.
Tap adjustment
Disconnect from electricity supply.
Open the oven doors and remove the fi xing screws
underneath the control panel. NB some models have a plate
under the facia held in place by the bottom fi xing screws.
Pull off all the control knobs.
Slide the control panel to the right and then pull forward.
Take care not to damage or strain the wiring.
Lift the control panel, pull forward.
Take care not to damage or strain the wiring.
To convert to another gas.
Unscrew the tap bypass screw.
Using a pair of long nose pliers carefully remove the bypass
screw and fi t the correct replacement screw. See the
Technical Data section at back of the book for the correct
size. Tighten the screw down.
Refi t the control panel.
Stick on label
Stick the appropriate label on to the data badge to indicate
the gas the appliance is now set for.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
See Technical data section at the back of this book for test
pressures.
The gas pressure can be measured at one of the left hand
hotplate burner jets. Lift off a burner head. Fit the pressure
gauge to the jet. Turn on the hotplate burner and turn on
and light one of the other burners.
After checking the pressure, turn the taps off and replace
the burner head.
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.