Conversion To Lp Gas - Falcon 1000 DF Guide De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

Conversion to LP Gas

Servicing - warning
This conversion must be performed by a competent person.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could invalidate
any warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest
of the appliance instruction, in particular for information on
Standards, cooker positioning, connection hose suitability
etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Conversion
Disconnect from electricity and gas before servicing. Check
appliance is safe when you have fi nished.
This appliance is CAT II 2H3+ . It is supplied set for G20
natural gas at 20millibar
A conversion kit for LP gas (G30 29mbar/G31 37mbar) is
supplied with the cooker.
Injectors
Remove pan supports burner caps and heads.
Undo the large brass nuts and remove the brass venturis.
Lift up the front of the hotplate top and disconnect the
ignition leads from the electrodes. Remove the hotplate top.
Remove old jets. Fit the new jets (see the table for correct
jets).
Tap adjustment
Pull off all the control knobs.
Open the oven door & grill door and remove the fi xing
screws underneath the control panel.
Remove the 3 fi xing screws at the top of the control panel.
Pull the control panel forward. Rest it on the open grill door
and the open right hand oven door.
To convert the control taps
Unscrew the tap bypass screw.
All manuals and user guides at all-guides.com
SERVICING - WARNING
24
Using a pair of long nose pliers carefully remove the bypass
screw and fi t the correct replacement screw. Tighten the
screw down.
See table for correct size.
Refi t the control panel.
Natural Gas
Injector Bypass Injector Bypass
Hotplate
Centre burner
165
Large Burners
120
Right front burner
95
LP Gas
96
107
57
54
82
40
39
64
32