Télécharger Imprimer la page

Horizont turbomax AN800 Notice D'utilisation page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
230V
/ 12V :
Connect the earth connection cable to the earth terminal (
fence connection cable to the fence terminal (
Operating and control:
230V
:
Plug the mains cable in a 230 V supply socket. After 1 se-
cond starts a test of LEDs and warning signal (LED 1 - 6, left
to right) - see Fig. 3. After this test, LEDs 1-6 goes out and an
acoustic warning signal will be generated and after 1 second
a slight tic-tac can be heard. The unit operates. The indica-
tion CONTROL (4) is illuminated green.
12V :
Connect the battery cable to the socket (Fig. 1a). Connect the
controller to a 12V wet battery (red + / black -), ensure that
the terminals are absolutely clean and the polarity is correct.
Use only rechargeable 12V- lead-acid batteries, during char-
ging lead-acid batteries must be placed in a well-ventilated
area.
Press the switch (Fig. 1b). After 1 second starts a test of LEDs and warning
signal (LED 1 - 6, left to right) - see Fig. 3. After this test, LEDs 1-6 goes out
and an acoustic warning signal will be generated and after 1 second a slight
tic-tac can be heard. The unit operates. In case of wrong polarity the cont-
roller will not operate.
The battery indicator light
permanent green
flashing red / green
permanent red
230V
/ 12V :
The 6 LEDs (1) indicate the fence voltage in 1000V steps. At least 3 lamps
should flash (3000V) to ensure sufficient voltage and fencing.
Possible reasons, when the voltage is too low:
a) with fence: heavy vegetation on the fence, insulator flash-over or fence
too long.
b) without fence: the energizer is faulty, see service.
Combined operation (230V
The energiser is connected to a 12V battery and the 230 mains. If the 230V
fails and is not available the energiser is supplied by the battery
cation CONTROL (4) changes from green to red.
(5) is illuminated:
= battery is fully charged
= battery must be charged
= battery is empty
the controller switches off !
+ 12V ):
). Connect the
).
the indi-
5