5.6 Mounting the endstop fins
Place the endstop fi ns onto the rack and secure them using a 3 mm Allen wrench. Their positioning limits the gate run.
Note: the gate schould not slam against the mechanical stop, when opening or closing.
5.7 Manually releasing the gearmotor
- Insert the trilobed key into the lock, push it in and turn it clockwise ....
..... open the small door and turn the release handle clockwise.
Trilobed key
WARNING: opening the door will
disengage the motor (i.e. it will not
function).
To operate the motor the release
mechanism must be fi rmly fastened.
Mechanical stop
Knob