Troubleshooting
PROBLEM
The appliance is not
working. The indicator
light above the ON/OFF
button
fails to come on.
The appliance does not
start the cooking process.
E0 is shown on one of the
displays
/
.
E2 is shown on one of the
displays
/
.
E3 is shown on one of the
displays
/
.
E4 is shown on one of the
displays
/
.
E5 or E6 is shown on one
of the displays
/
SDI 3500 A1
POSSIBLE CAUSE
The plug is not connected.
The appliance is damaged.
There is no vessel on the
respective hob
The vessel is not suitable
for induction hobs.
There is no vessel on the
respective hob
The vessel is not suitable for
induction hobs.
The temperature sensor
beneath the hob
defective or there is a short
circuit.
The appliance is being
supplied with too much
voltage (>270 V).
The appliance is not being
supplied with enough voltage
(<150 V).
The appliance has overheated.
.
POSSIBLE
SOLUTIONS
Connect the appliance to
a mains power socket.
Contact the Customer
Service department.
Place a suitable vessel on
/
.
the respective hob
Use a suitable vessel
(see the "Suitable
cookware" section).
/
.
Place a suitable vessel on
the respective hob
Disconnect the plug from
/
is
the mains power socket
and contact the Customer
Service department.
Check and ensure that the
appliance is connected
to a properly installed
mains power socket with
220–240 V ~ , 50 Hz.
Check and ensure that the
appliance is connected
to a properly installed
mains power socket with
220–240 V ~ , 50 Hz.
Disconnect the plug from
the mains power socket and
wait until the appliance has
cooled down. If the problem
should persist, please con-
tact Customer Services and
specify the error code.