Converting CS 1012
To convert the burners
,
Conversion to a different type of
gas should only be performed by an
authorized gas technician.
Turn off the main gas supply (if the
appliance has been installed) and
disconnect the appliance from the
main electrical power supply before
proceeding.
When converting to a different type of
gas, the jets and needle valves have to
be changed.
Maximum output
Gas type
Normal
Natural Gas
burner
LP Gas (Propane)
Fast
Natural Gas
burner
LP Gas (Propane)
Total
Natural Gas
output
LP Gas (Propane)
Minimum output
Gas type
Normal
Natural Gas
burner
LP Gas (Propane)
Fast
Natural Gas
burner
LP Gas (Propane)
10
All manuals and user guides at all-guides.com
BTU/hr
kW
5,700
1,65
5,000
1.45
10,600
3.10
9,300
2.75
16,300
4.75
14,300
4.2
BTU/hr
kW
775
0.227
1,010
0.296
1,550
0.454
1,500
0.439
The following jets and needle valves
should be installed into their respective
burners. Follow codes accordingly.
Code Jet size
(Ø mm)
Natural gas
Normal
110
burner
Fast
150
burner
LP Gas (Propane)
Normal
68
burner
Fast
92
burner
Code
Needle
valve size
(Ø mm)
1.10
42
0.42
1.50
60
0.60
0.68
29
0.29
0.92
40
0.40