IF JuNCTION BOX MOuNTING HOLES arE NOT
HOrIZONTaL:
a. Align slots on bracket with mounting holes in
junction box. Note: Bracket mounting holes must
be level after adapter is mounted.
b. Apply silicone caulk around junction box or on
adapter bracket.
c. Securely attach mounting adapter to junction
box using two screws supplied.
Mounting Adapter
Bracket Mounting
Holes - Horizontal
5. Apply caulk to the face of the adapter. This will seal
the back of the fixture to the adapter.
6. Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Junction box ground wire to
Green ground wire on fixture.
598-1132-06
Get user manuals:
See SafeManuals.com
Junction Box
Caulk
Caulk Face
of Bracket
Black to Black
white to white
3
7. Align wall light back-
plate and mounting
adapter holes. Secure
with two mounting
screws (included).
8. Reinstall reflector.
BuLB INSTaLLaTION
1. When re-lamping, turn power off and let bulb cool.
2. Pull glass shield down to remove from lamp holders.
3. Remove the old bulb by pushing the bulb towards
the right until the left side of bulb is clear of left
socket.
Important: use a clean glove or cloth when han-
dling the new bulb. Oil from your hand may cause
the bulb to crack when the fixture heats up and result
in premature failure. Use isopropyl (rubbing) alcohol to
clean the bulb if it is touched with your bare hands.
Lamp Holders
1
2
4. To insert new bulb, push bulb into the right socket
until the left side of bulb fits completely into left
socket.
5. Check that bulb is seated properly.
6. Securely push glass shield onto lamp holders.
Reflector
3
Glass Shield