ElEctRIcal cOnnectiOn
Fatal danger!
improper installation and improper electrical connection can
present a fatal hazard . hazards posed by electrical power must
be eliminated .
· Only have installation and electrical connection work performed by specialist
staff and in accordance with the applicable regulations (e .g . iec, vde etc .) .
· type of current and voltage must correspond to the specifications
· heed the regulations of local power supply companies .
· heed accident prevention regulations .
· never pull on the supply cable .
· do not bend the cable .
· do not set anything down on the cable .
· When using the pump in systems with temperatures of over 90°c a
corresponding heat-resistant connection cable must be used .
· during installation, hazards occur during sharp edges or burr .
· never transport pumps by carrying with the mains cable .
· there is a danger of injury through the pump falling .
assembling the power plug
connect the power cable to the pump as shown. Caution: Line voltage!
observe the required protective measures, national body regulations and
local provisions at all times. the cable cross-section may be no smaller
than 0.75 mm². use ferrules if using fine-wire cables.
46 eveneS heatinG PUMP he-ht