PURE Aquarium KIT
6.1. Maintenance and cleaning jobs
Observe the indicated maintenance and cleaning schedule to keep
your product in excellent working order.
Frequen-
Part
cy
Visually inspect the sponges; if they
Mechanical
are clogged, rinse them out or replace
filtration
them
Every
week
Check that the water level is between
Tank
the MIN and MAX marks and top it up
as needed.
Replace the 3ACTION cartridge (2
Every 15
Chemical
cartridges for the XL model) (par. 6.2
days
filtration
Rolling Filtration System)
Replace the mechanical filter sponge
(2 sponges for the XL model). For the
Every
Mechanical
L and XL models, replace the spong-
month
filtration
es closest to the water outlet nozzle
(par. 6.2)
Every 6
Clean the pump unit (par. 6.3)
Pump unit
months
6.2. Rolling Filtration System
To keep the filters working properly and ensure the best water con-
ditions in the aquarium, Askoll recommends that you replace the
sponges and cartridges according to a specific maintenance sched-
ule, the Rolling Filtration System (RFS).
This is very easy to do with the original Askoll maintenance kits,
available from your retailer (see product code in Chap. 9).
Two kits are available:
Askoll PURE FILTER MEDIA kIT M-L-XL, containing 1 me-
chanical filtration sponge and 2 3ACTION cartridges (1 kit per
month for PURE M and PURE L aquariums, 2 for the PURE XL
aquarium);
and:
Askoll PURE FILTER MEDIA kIT M-L-XL CONVENIENT, con-
taining 4 mechanical filtration sponges and 8 3ACTION cartridg-
es (1 kit every 4 months for PURE M and PURE L aquariums, 1
every 2 months for the PURE XL aquarium);
21
12
All manuals and user guides at all-guides.com
Replace the sponges and cartridges as follows:
1) After disconnecting the plug of each electric device, open the
2) Remove the sponges and cartridges and dispose of them ac-
Job
3) Replace the sponges and cartridges at the specified intervals
4) Close the filter cover.
The Askoll PURE
flashing) to replace the 3ACTION cartridge/s (Rolling Filtration Timer
– RFT). To turn off the RFT indication, simply press
To turn off the RFT function, refer to par. 5.1.1. - E.
6.3. Cleaning and servicing the pump unit
1) After disconnecting the plug of each electric device, remove the
2) Extract the pump unit (fig. 21).
3) Detach the intake tube and delivery tube (with delivery) from the
4) If necessary, replace the pump (dispose of it as indicated in
5) Turn the pump volute counterclockwise to remove it, then extract
6) Rinse the impeller under running water (fig. 24).
7) Clean the impeller's seat carefully with a non-abrasive brush
8) If necessary, also clean the intake tube, delivery tube and deliv-
9) Reassemble and restore the pump carefully along with the other
6.4. Cleaning the lighting unit
1) After disconnecting the plug of the lighting unit, remove the filter
2) Place the covers on a surface protected with a cloth so as not
22
filter cover.
cording to local regulations.
(par. 6.1).
timer will remind you every 15 days (icon
LED
filter cover and extract the pump unit cable from the fairlead seat
and cable guide.
volute (fig. 22).
Chap. 10), otherwise go to the next step.
the impeller (fig. 23).
(fig. 25).
ery under running water.
components, proceeding in the reverse order to the disassembly
procedure.
cover and the light cover.