Télécharger Imprimer la page

Askoll PURE M LED Manuel D'instructions page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PURE Aquarium KIT
There is also a demo mode (DEMO), which simulates the complete
daily cycle in a few seconds to highlight the potential off the led
lighting system when controlled by the integrated timer (point F).
IMPORTANT
Turning the light off manually with the button
turning the light off automatically at the set time do not disconnect
the lighting unit from the power supply.
The PURE
LED
aquarium timer does not need batteries. If there is a
mains power failure, the system maintains the user settings for at
least 12 hours.
A. Setting the clock time on first start up (hours and
minutes)
Once the lighting unit is connected to the power supply, the timer
waits for the time to be set (it displays icon
digits flash).
1) Set the hour by pressing
setting. Then press
to set the minutes.
2) Set the minutes by pressing
the setting. Press
to confirm. The time has now been set.
If you do nothing, the lighting system is set by default to turn on at
10:00 and turn off at 18:00. To set the on/off times to your preference
or to set the only manual mode, refer to point C.
B. Manual mode
Press
to turn on the day light (
on) and turn the light off completely, in that sequence.
C. Programming the automatic light on/off times
1) Hold down button
until the text "light" displays (wait for the
countdown 3..2..1  "light" to terminate).
2) The time digits will now display "Auto" and icons
flash. To set the only manual mode, press
displays. Confirm by pressing
3) Once you have set automatic mode "auto", icon
digits will flash. Set the on time (hour and minutes) in same way
as for the clock time (points 1 and 2, par. A).
4) Once you have set the on time, icon
flash. Set the off time (hour and minutes) in same way as for the
clock time (points 1 and 2, par. A).
5) Once you have finished, the timer will display the clock time
again.
6) The timer is now programmed to run the automatic daily light
cycle, as indicated at the start of this chapter.
d. Changing the clock time (hours and minutes)
If you need to change the clock time, proceed as follows:
1) Press and hold down
until the clock digits display "time" (you
must wait for 2 countdowns to complete: 3..2..1  "light" 
3..2..1  "time").
2) The icon
and the hour digits will flash: set the clock time
(hours and minutes) as indicated in par. A.
10
All manuals and user guides at all-guides.com
on the Timer and
and the two hour
to increase and
to decrease the
to increase and
to decrease
icon on), the night light (
and
until the text "man"
.
and the hour
and the hour digits will
E. Turning the RFT function on and off
The RFT is on by default (On). To turn it on/off, proceed as follows:
1) Press and hold down
must wait for 3 countdowns to complete: 3..2..1  "light" 
3..2..1  "time"  3..2..1  "RFT").
2) The clock digits display "On" and icon
deactivate (OFF) or activate (ON) the RFT function. Confirm by
pressing
.
3) Once you have finished, the timer will display the clock time
again.
When the RFT function is on, the timer will flash every 15 days to
remind you to do scheduled maintenance. To reset the indication,
press
.
F. Turning the dEMO function on and off
1) Hold down buttons
its display "DEMO" (you must wait for the countdown 5..4..3..2..1
 "DEMO" to terminate). The DEMO function is now active.
2) To turn DEMO mode off, press
time again.
g. Restoring the factory defaults (timer reset)
1) Press and hold down buttons
the clock digits display "RSET" (you must wait for 2 countdowns
to complete: 5..4..3..2..1  "DEMO"  5..4..3..2..1  "RSET").
2) The timer will now restore the factory default settings.
5.1.2. Filtration
icon
Always close the filter cover after the necessary oper-
ations have been performed, to prevent algae growing
on the filters due to their exposure to direct light.
will
Aquarium water, to provide the best habitat for fish and plants, must
be filtered continuously with mechanical, biological and chemical
filtration.
Mechanical filtration, which uses double layer sponges, removes
suspended particulates to keep the water clear. You can always
check the degree to which the sponges are soiled by simply opening
the filter cover.
Biological filtration, done by the nitrifying bacteria which grow in
the pores of the ceramic cylinders, minimises the level of toxic chem-
icals in the water, which are harmful for the aquatic fauna, transform-
ing the ammonia produced by the fish into nitrates. It takes around
4 weeks for a sufficient amount of bacteria for effective purification
to develop in the filtration media. This is why the first month of the
aquarium's life is critical, and the fish should be added only gradually,
to allow the nitrifying bacteria to take hold and multiply to a suitable
level.
Chemical filtration is done by the 3ACTION cartridge, which con-
tains a special mix of three ingredients:
Activated carbon for purifying the previously filtered water from
bad odours, colourants, pharmacological residues and other un-
desired compounds.
until the clock digits display "RFT" (you
flashes; press
and
simultaneously until the clock dig-
. The timer will display clock
and
simultaneously until
CAUTION
to

Publicité

loading

Ce manuel est également adapté pour:

Pure l ledPure xl led