DIP 4
Disabling of the ESA energy saving function.
With the ESA function enabled once opening or closing movements have been completed, the control unit is in maximum energy efficiency condition,
reducing absorption to minimum and disconnecting accessory outputs.
On: ESA energy saving function disabled.
Off: ESA energy saving function enabled (default).

BELT TENSIONING

To prevent the belt from remaining tensioned once the mechanical closing end-of-run is reached, a brief inversion is commanded in the opening direction.
This inversion can be adjusted (or excluded) , if necessary, following this procedure:
- Switch DIP 1 and DIP 2 to ON.
- PU2 selects the duration of the inversion, indicated by LED LD1:
LD1 1 flashing
inversion disabled
LD1 2 flashing
minimum inversion
LD1 3 flashing
medium inversion (Default)
LD1 4 flashing
maximum inversion
CAUTION: After programming, switch DIP 1 and DIP2 to OFF.
Carry out some test movements to check correct operations.
DEAD MAN MODE
Switching DIP to ON changes the control unit to DEAD MAN mode.
The PHOT input takes on the CLOSE key function (connect key with N.O. contact).
The S.S. input takes on the OPEN key function (connect key with N.O. contact).
The OPEN/CLOSE keys must remain pressed during the movement.
Opening the STOP input stops the motor. Simultaneous pressing of OPEN/CLOSE keys stops the motor.
CONFIGURATION OF BUILT-IN RECEIVER
(MANUAL STORAGE)
The control unit is equipped with a built-in radio module to receive ARC rolling-code remote controls, with a frequency of 433.92MHz.
Before using the remote control, please study the information with care, the storage procedure is shown as follows, the device is able to store up to 64
different codes.
Storage of a transmitter key with S.S. activation
- Press the PU2 key once for 1s, the LD1 LED emits 1 flash with 1s pause.
- Press the key of the transmitter to be stored with S.S. function within 10s, the 3 red LEDs light up for 1s, then, after storing, the receiver automatically
exits the programming phase.
Storing a transmitter key with Partial Opening activation function (10cm).
- Press the PU2 key once for 1s, the LD1 LED emits 1 flash with 1s pause.
- Press the PU2 key again, the LD1 LED flashes twice with 1s pause
- Press the key of the transmitter you wish to store with Partial Opening function within 10s, the 3 red LEDs light up for 1s then, after storing, the receiver
automatically exits the programming phase.
TCA closure has no effect on the Partial Opening function.
Partial opening can take place only if the panel is completely closed.
To exit programming without storing the transmitter, wait 10s.
Storage of a transmitter key with timed "Service Light" function
- Press the PU2 key once for 1s, the LD1 LED emits 1 flash with 1s pause.
- Press the PU2 key twice more, the LD1 LED will flash 3 times with 1s pause
- Press the key of the transmitter to be stored with the timed "Service Light" function within 10s, the 3 red LEDs light up for 1s then, after storing, the
receiver automatically exits the programming phase.
The "Service Light" is enabled for 90s each time the stored key is pressed.
Storage of a transmitter key with enabling of a bistable "Service Light"
- Press the PU2 key once for 1s, the LD1 LED emits 1 flash with 1s pause.
- Press the PU2 key again 3 times, the LD1 LED will flash 4 times with 1s pause
- Press the transmitter key to be stored with the bistable "Service Light" function within 10s, the 3 red LEDs light up for 1s then, after storing, the receiver
automatically exits the programming phase.
The "Service Light" is enabled or disabled each time the stored key is pressed.
Remote acquisition of a transmitter
If you already have a stored transmitter, others can be stored without accessing the control panel. Remote storage must be performed with the panel
completely open, regardless of the TCA setting. Proceed as follows:
1 Press the hidden key of the stored transmitter.
2 Press the key of the stored transmitter to be copied within 10s. The "Service Light" flashes.
3 Press the hidden key of the new transmitter to which the function is to be associated within 10s.
4 Press the key of the new transmitter to which you want to associate the function selected in point 2 within 10s. The "Service Light" is steady.
5 The new transmitter has been stored, the receiver exits the programming phase.
E.g.: key 1 of TX "A" contains the P.P. function that you want to assign to key 2 of the new TX "B"; press in sequence:
hidden key of TX A >> key 1 of TX A >> hidden key of TX B >> key 2 of TX B.
Deleting all transmitters from memory
- Keep the PU2 key pressed for 15s, the LD1 / 2/3 LEDs and the service light start flashing quickly and turn off when cancellation is complete.
- Release the PU2 key, the memory has been erased.
PLEASE NOTE:
Transmitters may not be stored during the opening/closing phases of the motor due to safety reasons.