Télécharger Imprimer la page

Panasonic WH-SQC09H3E8 Manuel D'utilisation page 18

Unité intérieure de pompe à chaleur air-eau
Masquer les pouces Voir aussi pour WH-SQC09H3E8:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 218
Q Q Signal inputs
L N =AC230V, Heat, Cool=Thermostat heat, Cool
Optional Thermostat
terminal
Dry contact Vcc-Bit1, Vcc-Bit2 open/short
(System setup necessary)
SG signal
Switching SW (Please connect to the 2 contacts
controller)
Dry contact Open=Heat, Short=Cool
Heat/Cool SW
(System setup necessary)
Dry contact Open=Comp.OFF, Short=Comp.ON
External comp.SW
((System setup necessary)
DC 0~10V ((System setup necessary)
Demand signal
Please connect to the DC 0~10V controller.
Q Q Outputs
AC230V N=Neutral Open, Close=mixture direction
Mixing valve
Operating time: 30s~120s
Pool pump
AC230V
Solar pump
AC230V
Zone pump
AC230V
Q Q Thermistor inputs
Zone room
PAW-A2W-TSRT
sensor
Buffer tank
PAW-A2W-TSBU
sensor
Pool water
PAW-A2W-TSHC
sensor
Zone water
PAW-A2W-TSHC
sensor
Solar sensor
PAW-A2W-TSSO
Recommended External Device Specification
This section explains about the external devices (optional)
recommended by Panasonic. Please always ensure to use the
correct external device during system installation.
For optional sensor.
1. Buffer tank sensor: PAW-A2W-TSBU
Use for measurement of the buffer tank temperature.
Insert the sensor into the sensor pocket and paste it on the
buffer tank surface.
Dimensions (mm)
brown
2. Zone water sensor: PAW-A2W- TSHC
Use to detect the water temperature of the control zone.
Mount it on the water piping by using the stainless steel metal
strap and contact paste (both are included).
Dimensions (mm)
35
3. Outdoor sensor: PAW-A2W-TSOD
If the installation location of the outdoor unit is exposed to direct
sunlight, the outdoor air temperature sensor will be unable to
measure the actual outdoor ambient temperature correctly.
In this case, optional outdoor temperature sensor can be fixed
at a suitable location to more accurately measure ambient
temperature.
Dimensions (mm)
46
18
blue
black
40
93
70
70
93
4. Room sensor: PAW-A2W- TSRT
Install the room temperature sensor to the room which requires
room temperature control.
5. Solar sensor: PAW-A2W-TSSO
Use for measurement of the solar panel temperature.
Insert the sensor into the sensor pocket and paste it on the solar
panel surface.
6. Please refer to the table below for sensor characteristic of the
sensors mentioned above.
Temperature
Resistance
(°C)
(kΩ)
30
5.326
25
6.523
20
8.044
15
9.980
10
12.443
5
15.604
0
19.70
-5
25.05
-10
32.10
-15
41.45
-20
53.92
-25
70.53
-30
93.05
-35
124.24
Ø6
-40
167.82
For optional pump.
Power supply: AC230V/50Hz, <500W
Recommended part: Yonos 25/6: made by Wilo
For optional mixing valve.
Power supply: AC230V/50Hz (input open/output close)
Operating time: 30s~120s
Recommended part: 167032: made by Caleffi
Dimensions (mm)
30
86
86
Dimensions (mm)
blue
black
brown
40
Temperature
Resistance
(°C)
(kΩ)
150
0.147
140
0.186
130
0.236
120
0.302
110
0.390
100
0.511
90
0.686
80
0.932
70
1.279
65
1.504
60
1.777
55
2.106
50
2.508
45
3.003
40
3.615
35
4.375
60
Ø6

Publicité

loading

Ce manuel est également adapté pour: