Host <portID> "Port failover state is <failoverstate>, port state is
<state>"
Host <portID> "Port not connected to fabric like <portID>"
Host <portID> "Port not configured as host like <portID>"
Hôte<portID>« Comme port pas FC<portID>"
Host <portID> "Port state is <state>, not ready like <portID>"
Host <portID> "Port WWN not found on FC Fabric attached to <portID>"
Host <portID> "Host port connected to FC Fabric switch port without NPIV
support"
Host <portID> "Host is not seen by multiple nodes, only seen from node
<nodeID>"
host Exemple 1
Component -------Summary Description-------- Qty
Host
Ports not configured symmetrically
Component -Identifier- ------------Detailed Description------------
Host
Port:0:1:1
host Mesure 1
Utilisez les commandes showport, showport -par, et controlport de CLI afin de configurer le port
1:0:1 pour le mode point (connexion à la matrice de commutation) ou configurez le port 0:1:1 en mode
boucle (pour la connexion directe).
cli% showport -par 0:0:1 1:0:1
N:S:P Connmode ConnType CfgRate MaxRate Class2
IntCoal
TMWO
0:1:1 host
loop
disabled enabled n/a
1:0:1 host
point
disabled enabled n/a
host Exemple 2
Component ------Summary Description------- Qty
host
Hosts not seen by multiple nodes
Component -Identifier- ------------------Detailed
Description-------------------
host
testhost
node 3
host Mesure 2
Utilisez les commandes showvlun -v et showhost de CLI pour déterminer le problème signalé. Si
l'hôte est défini avec uniquement des connexions provenant d'un nœud, utilisez la commande de CLI
Port not connected to fabric like Port:1:1:1
Smart_SAN
auto
8Gbps
auto
8Gbps
Host is not seen by multiple nodes, only seen from
1
UniqNodeWwn VCN
disabled disabled
disabled disabled
1
Résolution des problèmes
disabled