Cabling <cageID> "Cabled to <nodelist>, remove a cable from <nodelist>"
Cabling <nodeID> "No cabling data for <nodeID>. Check status of <nodeID>"
Cabling <cageID> "Cage is connected to too many node ports (<portlist>)"
Cabling <cageID> "Cage has multiple paths to <portlist>, correct cabling"
Cabling <cageID> "I/O <moduleID> missing.
<cageID> I/O <moduleID>"
Cabling <cageID> "Cage not connected to <nodeID>, move one connection from
<nodeID> to <nodeID>"
Cabling <cageID> "Cage connected to different ports <node&portID> and
<node&portID>"
Cabling <cageID> "Cage connected to non-paired nodes <node&portID> and
<node&portID>"
Cabling <cageID> "Check connections or replace cable from
(<cage,module,portID>) to (<cage,module,portID>) - failed links"
Cabling <cageID> "Check connections or replace cable from
(<cage,module,portID>) to (<cage,module,portID>) - links at
<speed>"
Cabling <nodepairID> "<node&portID> has <count> cages, <node&portID> has
<count> cages"
Cabling <cageID> "Cable in (<cage,module,portID>) should be in
(<cage,module,portID>)"
Cabling <cageID> "No PDs installed in cage, cabling check incomplete"
Cabling <cageID> "<node&portID> has <count> cages connected, Maximum is
<count> (<cagelist>)"
Cabling <cageID> "<node&portID> should be cabled in the order: (<cagelist>)"
cabling Exemple 1
Component -Summary Description- Qty
Cabling
Bad SAS connection
Component -Identifier- ----------------------------------------Detailed
Description-----------------------------------------
Cabling
cage7
0, DP-2) to (cage7, I/O 0, DP-1) - links at 6Gbps
cabling Mesure suggérée 1
Utilisez la commande showcage de CLI pour vérifier que les deux cages sont disponibles via deux ports,
avant de remplacer le câble indiqué dans le message d'erreur.
cli% showcage cage6 cage7
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
6 cage6 0:1:1
7 cage7 0:1:1
cabling Exemple 2
Cabling
1
Check connections or replace cable from (cage6, I/O
1 1:1:1
0
0 1:1:1
1
Check status and cabling to
RevA RevB Model FormFactor
10 28-30 1.76 1.76 DCS8
10 27-30 1.76 1.76 DCS8
Résolution des problèmes