Product Selection, Project Engineering and Modification
US
5.2
External Attached Components
US
(Cable Entries, Stopping Plugs, Breathers)
US
Drilled holes are generally fitted with the components intended for the application at the
US
factory.
US
If customers intend to fit the components in the holes themselves, dust and transport
protection is provided for the openings in the enclosure (adhesive tape with a warning
US
note or plastic caps) at the factory.
US
US
5.2.1 Fitting of Attached Components by R. STAHL
 Give the following information to R. STAHL:
US
- Type
US
- Data sheet
- Quantity, manufacturers and approvals of the components that are to be attached.
US
- Type of protection
US
US
R. STAHL
• will check whether the components, quantity and position correspond with the approval
US
• will mount the components
US
• will update the order documentation
US
• will carry out a routine test
• will attach a new rating plate if the technical data has changed.
US
US
5.2.2 Fitting of Attached Components by the Customer
US
Selecting add-on components
US
We recommend fitting the following add-on components to the enclosure:
US
Cable entry
• For electrical lines that are permanently installed: Cable entries for electrical lines that are
US
permanently installed
US
• For electrical lines that are not permanently installed: Cable entries with strain relief.
US
Sealing unused entries
US
• Use stopping plugs that comply with the type of protection required.
Draining and equalising pressure
• Breather.
 Equip the device carefully and in accordance with the safety notes (see "Safety" chapter).
 Refer to the specifications on the device's rating plate to help you determine which
components and seals to use and what operating temperatures they will need to be able
to withstand.
 Calculate the usable area (collision frame) for add-on components, see Chapter 5.1.2 and
5.2.2.
 Make the diameter of the drilled holes match the dimensions of the built-in parts or their
seals.
 The use of add-on components with a flat seal (gasket) is preferred.