FOR SERVICE TECHNICIAN'S USE ONLY
18. If still no display, unplug oven or disconnect power.
19. Replace Control Panel Assembly.
20. Reassemble all parts and panels before operating.
21. Plug in oven or reconnect power.
22. Verify operation is normal.
User Interface not reacting to touch
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait 10
seconds, and power on).
1.
Enter the Diagnostics menu, and then touch POWER.
2.
To reset Touch Calibration: unplug oven or disconnect power, wait 10
seconds, and then plug in oven or reconnect power. If still no response,
go to Step 3.
3.
Unplug oven or disconnect power.
4.
Replace Control Panel Assembly.
5.
Reassemble all parts and panels before operating.
6.
Plug in oven or reconnect power.
7.
Verify operation is normal.
8