FOR SERVICE TECHNICIAN'S USE ONLY
6.
Disconnect connector J8 from the Copernicus Appliance Manager.
Measure the resistance between connectors J8‑2 and P5‑1. It should be
500 Ω to 3000 Ω at 77°F (25°C).
Upper Copernicus
Appliance Manager
P5
J8
Lower Copernicus
Appliance Manager
P5
1
2
J8
7.
If the resistance check is outside the range, replace the door latch
assembly.
8.
Verify that the resistance between connectors J8‑2 and P5‑1 is 500 Ω to
3000 Ω at 77°F (25°C).
9.
If all checks were correct, replace Copernicus Appliance Manager.
10. Reassemble all parts and panels before operating.
11. Plug in oven or reconnect power.
12. Verify operation is normal. Enter Diagnostics mode, select "Error
Diagnostics," and clear the history.
N
WH
YL
1
2
Upper Motor Door Latch
3
4
5
6
7
1
WH
2
N
WH
YL
1
2
Lower Motor Door Latch
3
4
5
6
7
WH
FAILURE
ERROR
LIKELY FAILURE CONDITION
E1
Over temperature (main/upper oven)
F6
E3
Over temperature (lower oven)
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait 10
seconds, and power on).
PROCEDURE: Before proceeding, verify the error code by entering the
Diagnostics mode and selecting "Error Diagnostics."
1.
Unplug oven or disconnect power.
2.
Check for elements shorted to ground. Check resistance of elements:
a. PX4‑2 and PX3‑2 to check Broil element (13.2 Ω to 14.6 Ω)
b. PX1‑1 and PX3‑2 to check Bake element (19 Ω to 21 Ω)
c. PX1‑3 and PX3‑2 to check Convect element (16.6 Ω to 18.4 Ω)
3.
If there is a short to ground, replace the corresponding element.