Velleman HAM982K Notice D'emploi page 6

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SOUND
1 short beep
2 short beeps
5 short beeps
1 long beep
1 short beep/30s
continuous beep every 0.5s • exit delay time
2 beeps + 5 beeps
b. Connections
BATTERY: connect the red (+) wire to the positive and the black (-) wire to the negative terminal of the battery. The
battery should be of the 12V / 1.2Ah sealed lead acid rechargeable type. It is protected by a 2.5A resettable
fuse and is charged by a current limiting regulated voltage source in the system.
1, 2 the device requires a 16.5Vac power supply, min. 1.5A at 50 or 60 Hz. The primary side of the transformer
must be connected to an unswitched receptacle.
3 This terminal provides an unswitched +12V output power referring to the common ground. It gives continuous
output power, even if the device is unarmed. Suitable for e.g. smoke detectors, control keypads etc. This
terminal is equipped with a 750mA resettable fuse.
4 This terminal provides a switched +12V output power referring to the common ground when the system is
armed. It is provided for devices that require switched power for resetting, such as glass-break detectors and
smoke detectors that require a power-down to reset. This terminal is equipped with a 750mA resettable fuse.
3+4 These terminals share the same power bus. Combined power for these outputs should not exceed 750mA.
5 Common ground (-)
6 This terminal provides a continuous +12V output power at normal (= no alarm) condition that is switched off
when an alarm occurs. It is intended for alarm devices with a built-in battery that remain quiet as long as there
is an incoming voltage (hold-off voltage) and that are activated (on battery power) when the voltage is cut.
7 This terminal provides a continuous +12V output power upon and after an alarm condition until the system is
disarmed or reset by the user code. It is equipped with a 2.5A resettable fuse. This output is intended for alarm
devices that switch on when there is incoming power (e.g.: SV/PSL3x siren + strobe).
HAM982K_v2
successful key entry
successful code entry for the function
• wrong code
• unauthorized command attempted
• code entry time expired, 10s max. per digit is allowed
exit delay expired, system is armed
• AC power failure
• weak battery
• entry delay time
• DAP jumper is on
system cannot be armed instantly due to ARM PROHIBITED
MEANING
6
VELLEMAN

Publicité

Table des Matières
loading

Table des Matières