Replacement Parts; Troubleshooting - Panasonic ES-SL83 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Replacing the system outer foil
1. Press the system outer foil release
buttons and pull down the system
outer foil.
2. Align the front side of the foil
frame with the system outer foil
mark ( ) and insert them firmly
together.
The system outer foil cannot be
reversely attached.
Always insert the system outer foil to the
foil frame when attaching to the shaver.
Replacing the inner blades
1. Remove the inner blades one at a
time.
Do not touch the edges (metal parts) of
the inner blades to prevent injury to your
hand.
2. Insert the inner blades one at a
time until they click.

Replacement parts

Replacement parts are available at your dealer or Service
Center.
Replacement parts for
ES - SL83
14
PB013383 - ES-SL83_
(01EN)_05-19-16.indd 14
1
1
System outer foil
WES9087
Inner blades
WES9068
System outer foil
WES9013
and inner blades

Troubleshooting

Problem
2
Trimmed hairs fly
all over.
System outer foil
gets hot.
The blades do not
dry.
2
The odor is getting
stronger.
You do not get as
close a shave as
before.
Action
This can be improved by cleaning
every time after shaving.
Clean the blades with the brush.
Replace the system outer foil if it is
damaged or deformed.
(See page 13)
The blades may not dry quickly due
to temperature conditions.
The blades can be dried more easily
by removing for drying.
This can be improved by cleaning
every time after shaving.
This can be improved by cleaning
every time after shaving.
Replace the system outer foil and/or
inner blades.
Expected life of system outer foil
and inner blades:
System outer foil:
Approximately 1 year
Inner blades:
Approximately 2 years