Malfunctions
Malfunction
Machine without function
Brush unit or suction unit cannot be
turned off
Brush does not rotate
Poor suction performanceFloor re-
mains wetDrain water is not
absorbed
Suction unit switches off
Insufficient cleaning solution supply
74
Possible causes
Machine is switched off
Battery disconnection socket not
connected
Main fuse is defective
Battery discharged or defective, Bat-
tery charger defective
Batteries defective
Error in the electronic system or in
the control panel
Brush drive switched off
Main fuse is defective
Motor rotates, brush does not
Suction not switched on
Suction hose not connected
Squeegee not on the floor
Blades worn out
Hose or squeegee clogged (e.g.
pieces of wood, remnants)
Suction filter clogged
Recovery tank full
Recovery tank contaminated
Cleaning solution tank empty
Cleaning solution volume set too low • Adjust cleaning solution volume
Cleaning solvent button switched off • Press cleaning solvent button
Troubleshooting
• Turn the key
• Connect the battery disconnection
socket with the machine
• Check/replace fuse
• Contact your service partner
• Load batteries
• Contact your service partner
• Contact your service partner
• Contact your service partner
• Press Brush button
• Replace fuse
• Drive belt broken
• Contact your service partner
• Press suction unit button
• Connect suction hose
• Check suction nozzle suspension
for functionality
• Replace blades
• Remove any foreign matter
• Remove any foreign matter
• Drain recovery tank
• Check battery monitoring
• Check fuse
• Check recovery tank and clean it, if
necessary
• Check cleaning solution tank
Page
65
65
67
65
65
65
68
68
73
65
70
71