R
ALED SLIPFITTER 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RC lighting fixtures. Our goal is to design the best quality products to get the job done right. We'd like to hear your comments.
Call the Marketing Department at 888-722-1000 or email: marketing@rclighting.ca
ON-OFF WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. Units ordered with (/347V) suffix are 347V, 60Hz.
For Non-Dimming, follow the wiring directions as in fig. 1.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply ground.
(+)LINE
(-)COMMON
GROUND
GROUND
PHOTOCELL INSTALLATION
Photocell may be installed in the field. Apply weatherproof
silicone sealant to all plugs and unused conduit entries.
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
PHOTOCELL
PHOTOCELL
RC fixture designs are protected under U.S. and International Intellectual Property laws.
Patents: US: pat. D587,839; CN: ZL200830272893.0; MX: 28396, TW: pat. 96304793-U02; CA: D RC Lighting LLC
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during
installation, operation or maintenance.
Easy Installation & Product Help
Tech Help Line
©2013 RC LIGHTING, LLC
Call our experts 888 722-1000
Northvale, New Jersey 07647 USA
BLACK
LIGHT
Fig. 1
WHITE
FIXTURE
BLACK
LIGHT
"COM"
WP2FC
WHITE
FIXTURE
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. For 0-10V Dimming, follow the wiring directions
as in fig. 2.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to
the output.
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.