ALED 50W -150W WITH UNIVERSAL ARM INSTRUCTIONS
Thank you for buying RC lighting fixtures. Our goal is to design the best quality products to get the job done right. We'd like to hear your comments. Call the Marketing
Department at 888-722-1000 or email: marketing@rclighting.ca
MOUNTING FIXTURE TO THE POLE
1. Remove the Arm Cover from the Arm.
2. Feed supply wires which are already pulled out from the
pole through the bracket into the Arm.
3. Make necessary connections inside the Arm and knot
wires for strain relief.
4. Slide the metal hanger plates at the back of the Arm to
the mounting hooks of the bracket on the pole,to secure
the fixture to the pole.
5. Replace the Arm Cover. Be sure the Gasket on Arm
Cover is in place. Tighten Screws and add the Plugs.
Secure Pole cap. Tighten Set screw at the bottom of the
arm.
Pole (Not provided)
Bracket
Mounting Hooks
FIG.4
Fixture
Arm
Arm Cover Gasket
Arm Cover
screw
Plug
Metal Hanger plates
ON-OFF WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. Units ordered with (/347V) suffix are 347V, 60Hz.
For Non-Dimming, follow the wiring directions as in fig. 5
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply ground.
(+)LINE
(-)COMMON WHITE
GROUND GROUND
PHOTOCELL INSTALLATION
Wire the photocell as shown below.(Fig.6)
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
PHOTOCELL
PHOTOCELL
BLACK
LIGHT
FIXTURE
FIG.5
BLACK
LIGHT
"COM"
WP2FC
WHITE
FIXTURE
FIG.6