9. Specifications

9.2 Safety-related characteristic values

Power supply circuit CPT62I0
Max. input voltage
Max. input current
Max. input power
Max. internal capacitance
Max. internal inductance

9.3 Ex approvals

Logo
Description
EU declaration of conformity for CPT62I0
EMC directive
EN 61326 emission (group 1, class B) and immunity (portable
equipment)
Pressure equipment directive
PS > 200 bar; module A, pressure accessory
RoHS directive
ATEX directive
Hazardous areas
Ex i Zone 1 gas
EAC
EMC directive
Pressure equipment directive
Hazardous areas (see approval)

9.4 Certificates

Certificate
Calibration
Recommended
recalibration interval
Approvals and certificates, see website
For further specifications see WIKA data sheet CT 11.02 and the order documentation.
WIKA operating instructions, reference pressure sensor, model CPT62I0
U
= DC 10.4 V
i
I
= 100 mA
i
P
= 500 mW
i
C
= 600 nF
i
L
negligible
i
II 2G Ex ib IIC T4
II 2G Ex ib IIC T4 Gb
Ta = -20 ... +50 °C
Standard: 3.1 calibration certificate per DIN EN 10204
Option: DKD/DAkkS calibration certificate
1 year (dependent on conditions of use)