BINDING THE WIRELESS THERMOSTAT AND RF REcEIVER

2.2.5 ON/OFF Switch

The temperature dial is used to turn the system ON and OFF.
Turn the dial to the left until the displayed temperature is lower
or equal than 10 ºc in order to turn the system off. Turn the dial
to the right until the displayed temperature is more than 10 ºc in
order to turn the system ON again.
2.2.6 Activation of the installation menu
Rotate the setting ring fully to the left until the minimum value is
shown. When the value starts flashing, touch and hold on left or
right touch zones for approximately 10 s.
10s.
The maximum temperature limit is now displayed. The setting
can be changed using the setting ring. There is no need to
confirm the value.
3 BINDING THE WIRELESS THERMOSTAT AND RF RECEIVER
The binding operation described below is required if:
Any of the system components (Room Thermostat or RF
Receiver) are replaced.
The RF Receiver has incorrect or no binding data stored
(e.g.when pre-bound system pack components have been
mismatched).
?
N O T E
During the binding procedure keep approximately 1m distance between
the Room Thermostat and the RF Receiver.
1 Hold button on RF Receiver for 15 seconds in order to
remove all the configurations. LED will flash red 0.1 sec ON,
and 0.9 sec OFF.
2 Hold button on RF Receiver for 5 seconds. LED will flash red
for 0.5 sec ON, and 0.5 sec OFF.
5
PMML0411A rev.1 - 04/2016
10s.
LED
Press here
While this setting is flashing, touch the left touch zone briefly
to display the minimum temperature limit. This can also be
changed using the setting ring.
The thermostat cannot be used to turn the system on and off
unless the limit for minimum temperature is set to a value lower
than 11ºc (Ex: 5ºc)
The installation menu is closed automatically after 10 seconds
of inactivity.

2.2.7 Reset to default

Rotate the setting ring fully to the left until the minimum
temperature is shown.
When the value starts flashing, touch and hold on left and right
touch zones for approximately 10 s. The maximum temperature
limit is now displayed flashing, touch the left touch zone briefly.
When the minimum temperature limit is flashing, touch again the
left touch zone.
The symbol
appears on the screen, touch and hold during
10 s the left touch zone and the device resets the default
settings.
3 Bind the thermostat. Touch and hold on the left touch zone
for approximately 10 seconds.
10s
4 The screen for binding the RF Receiver is now displayed.
5 When the symbol "bo" is flashing, rotate the setting ring until
the "Co" symbol is shown.
6 Briefly touch the left touch zone to send the binding signal,
at which point the symbol
will flash several times.