11. GENERAL MAINTENANCE
6. Clean the platen with a cloth moistened with alcohol.
7. Remove any dust or glue from the detection area of the sensors and paper path with a soft cloth.
8. Remove the supply holder rollers from the supply holder unit. Remove any dust from the recessed
portions of the base and wipe glues from the rollers with a slightly moistened soft cloth.
Supply Holder Base

11.2 COVERS

The covers should be cleaned by wiping with a dry cloth or a cloth slightly dampened with a mild detergent
solution.
NOTE:
Clean printer cover with an electrostatic free cleaner for automated office equipment.
1. DO NOT POUR WATER directly onto the printer.
2. DO NOT APPLY cleaner or detergent directly onto any cover.
3. NEVER USE THINNER OR OTHER VOLATILE SOLVENT on the plastic covers.
4. DO NOT clean the covers with alcohol as it may cause them to discolour, loose their shape or
develop structural weakness.
Platen
Black mark/Feed gap sensor
WARNING!
E11-2
ENGLISH VERSION EO1-33005
11.2 COVERS
Fig. 11-2
Recessed portion of the base
Supply Holder Roller
Fig. 11-3