Vente Unique Vogue Spa Installation Et Mode D'emploi page 43

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Utilities – GFCI Test Feature
Not Available on CE Rated Systems.
A GFCI is an important safety device and is required equipment on a hot tub installation.
Your spa may be equipped with a GFCI Protection feature. (UL rated systems only.) If your spa has this feature enabled by the manufac-
turer, the GFCI Trip Test must occur to allow proper spa function.
Within 1 to 7 days after startup, the spa will trip the GFCI to test it. (The number of days is factory programmed.) The GFCI must be reset
once it has tripped. After passing the GFCI Trip Test, any subsequent GFCI trips will indicate a ground fault or other unsafe condition and
the power to the spa must be shut off until a service person can correct the problem.
Sub-Menu Detail – Utilities - GFCI Trip
Main Screen
Press Menu/Select
repeatedly until UTIL (Utilities)
appears in the LCD.
To FIRST item in
Main Menu
(TEMP Range)
Only if GFCI
is enabled
To next item in
Info Menu
(A/B°)
Forcing the GFCI Trip Test
The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu.
The GFCI should trip within a few seconds and the spa should shut down. If it does not, shut down the power and manually verify that a
GFCI breaker is installed and that the circuit and spa are wired correctly. Verify the function of the GFCI with its own test button. Restore
power to the spa and repeat the GFCI Trip Test.
Once the GFCI is tripped by the test, reset the GFCI and the spa will operate normally from that point. You can verify a successful test by
navigating to the above menu. PASS should appear after a temp button is pressed from the GFCI screen.
The end-user must be trained to expect this one-time test to occur and how to properly reset the GFCI.
Warning:
If freezing conditions exist, a GFCI should be reset immediately or spa damage could result. The end user should always be trained to test
and reset the GFCI on a regular basis.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815,
7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. Allmaterial copyright
of Balboa Water Group.
One of these screens
will appear.
Only appears
if a GFCI test
has been
*****
passed.
Or wait to revert
Waiting a few seconds inside the GFCI Menu will allow the screen to return to normal operation.
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message - every 1/2 second
A temperature button, used for "Action"
Menu/Select button
Waiting time that keeps the last change to a menu item.
*****
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
When the GFCI trips,
the spa will shut down.
After the breaker is
TRIP may also
reset, PASS will
appear briefly
appear in this menu
under certain
and the spa will
circumstances.
operate normally.
If the GFCI does
The GFCI will be tripped
NOT trip, GFCI FAIL
at a random interval.
(see page 22)
will appear and Spa
will not operate.
*****
Or wait to revert
Indicates a Menu Item that
Depends on a Manufacturer
Configuration and
may or may not appear.
*****
Or wait to revert
42

Publicité

Table des Matières
loading

Produits Connexes pour Vente Unique Vogue Spa

Ce manuel est également adapté pour:

Tp500Tp500s

Table des Matières