Mode – Ready and Rest
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is known as the
"primary pump."
The primary pump can be either a 2-Speed Pump 1 or a circulation pump.
If the primary pump is a 2-Speed Pump 1, Ready Mode (indicated by
maintain a constant water temperature, heat as needed, and refresh the temperature display. This is known as "polling."
Rest Mode (indicated by
may not show a current temperature until the primary pump has been running for a minute or two.
Circulation Mode (See Page 4, under Pumps, for other circulation modes)
spa will maintain set temperature and heat as needed in Ready Mode, without polling.
Sub-Menu Detail – MODE – Ready and Rest
when in Circulation Mode.
Main Screen
Menu/Select
Press
repeatedly until MODE
appears in the LCD.
To next item in
Toggle between Ready (indicated by
Main Menu
If not toggled
Menu/Select
Pressing
Ready Mode will allow the spa to Poll and determine a need for heat. The panel will maintain a "current" temperature display.
Rest Mode will not Poll and will only heat during filter cycles. The panel will not display a current temperature at all times.
Main Screen
1 Hour
The Main Screen will display RUN PUMP FOR TEMP if the primary pump has not run for over 1 hour.
The Main Screen will display normally during Filter Cycles or when the spa is in use.
If the primary pump has been off for an hour or more, when any function button, EXCEPT Light, is pressed on the panel,
the pump used in conjuncton with the heater will run so that temperature can be sensed and displayed.
Ready-in-Rest Mode
appears in the display if the spa is in Rest Mode and "Jets" is pressed. It is assumed that the spa is being used and will heat to set
temperature. The primary pump will run until set temperature is reached, or 1 hour has passed. After 1 hour, the System will revert to Rest
Mode. This mode can also be reset by entering the Mode Menu and changing the Mode.
Sub-Menu Detail – MODE – Ready-in-Rest
Main Screen
Main Screen
Press "Jets" button
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815,
7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. Allmaterial copyright
of Balboa Water Group.
Main Screen
To Set
*****
Waiting a few
seconds reverts to
original settings
) and Rest (indicated by
when the display is toggled will go to Main Screen.
) will circulate water periodically, using Pump 1 Low, in order to
. Since the primary pump is always running, the
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message - every 1/2 second
A temperature button, used for "Action"
Menu/Select button
Waiting time that keeps the last change to a menu item.
*****
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
).